2018年4月18日星期三

2018年4月11日星期三

VELASII-45W Diode Laser for ENT treatment

GIGAA LASER can customized the VELASII-45W (30W 980nm+15W 1470nm) medical diode laser for ENT treatments.
With the two-wavelengths, the ENT-surgeon can select the appropriate wavelength for each indication according to the ideal absorption properties and penetration depth for the respective tissue and thus take advantage of both 980 nm (hemoglobin) and 1470 nm (water).
...

donna@gigaalaser.com

GIGAA LASER attend the CMEF



donna@gigaalaser.com

2018年1月17日星期三

1470nm medical laser and radial fiber for EVLA (endovenous vein laser ablation)


Using Guide for Surgical Handpiece Set

Connect Part1 and Part2, put the part 1 to the part 2 is OK, please keep them tightly. Then the part 1 + part 2 = part 4

Insert the fiber to part 3


Connect Part and Part4 by screw.

Safety Goggles for Animal


1940nm diode laser for varicose vein treatment

Medium and long-term outcomes of endovenous treatment of varicose veins with a 1940nm diode laser: critical analysis and technical considerations
Background: Introduction of the endovenous laser technique for treatment of varicose veins triggered a efforts to identify an ideal wavelength, capable of producing the highest possible selective damage with the greatest safety and lowest incidence of adverse effects.
Objectives: Assess medium to long term results of 1940nm diode laser treatment of varicose veins, correlating parameters used with durability of the anatomic outcome.
Methods: This was a retrospective study of patients diagnosed with Chronic Venous Insufficiency at clinical stages CEAP C2 to C6 who underwent thermal ablative treatment of trunk varicose veins using a 1940nm wavelength laser with a radial emission optical fiber, from April 2012 to July 2015. A systematic review was conducted of electronic medical records to obtain demographic and clinical data, including postoperative follow-up duplex ultrasound findings.
Results: Te average age of the 41-patient sample was 53.3 years and 37 patients were women (90.2%). Te average follow-up time was 803 days. Te average caliber of the treated veins was 7.8 mm. Te immediate success rate was 100% with an average LEED of 45.3 J/cm. Te late success rate was 95.1%, and two recanalizations were observed around 12 months after ablation. There was no recanalization in veins treated with a LEED greater than 30 J/cm. Conclusions: The 1940nm laser proved to be safe and effective in venous segments up to 10 mm in diameter, with the parameters proposed, over medium to long term time follow-up.
...
donna@gigaalaser.com